Skip to content
Burner.wikiKNOWLEDGE HUB
Series guide

Riello RS Series

Riello RS gas-burner families include staged and modulating versions. In the documented designation system, /M identifies mechanical-cam modulation, /E identifies electronic-cam control and TC identifies a standard-length combustion head. Selection requires the complete designation, firing diagram and gas-train requirements.This guide compares common models, naming logic, selection checks, and related model pages.

24 models in this seriesRielloGas Burners

What Is the RS Series?

The Riello RS Series family is a focused product group within Riello gas burners. Engineers usually evaluate these models by application fit, electrical and mechanical compatibility, replacement risk, and the original burner control sequence.

Model Naming Logic

Use the manufacturer documentation for the exact subfamily and complete designation. Do not infer voltage, safety timing, torque, pressure or certification from a shared prefix.

Models in This Series

ModelTypeKey DataPage
RS 34 TCGas Burner70/130 - 390 kW | Natural Gas | Two-stage progressiveView specs
RS 34/1 TCGas Burner70 - 390 kW | Natural Gas | One-stageView specs
RS 44 TCGas Burner101/203 - 550 kW | Natural Gas | Two-stage progressiveView specs
RS 44/1 TCGas Burner100 - 550 kW | Natural Gas | One-stageView specs
RS 50 TCGas Burner116/290 - 580 kW | Natural Gas | Two-stage progressiveView specs
RS 64/M TCGas Burner150 - 850 kW | Natural Gas | ModulatingView specs
RS 70 TCGas Burner192 - 814 kW | Natural Gas | Two-stage progressiveView specs
RS 70/M TCGas Burner150 - 814 kW | Natural Gas | ModulatingView specs
RS 100 TCGas Burner232 - 1163 kW | Natural Gas | Two-stage progressiveView specs
RS 100/M TCGas Burner150 - 1163 kW | Natural Gas | ModulatingView specs
RS 130 TCGas Burner372 - 1512 kW | Natural Gas | Two-stage progressiveView specs
RS 130/M TCGas Burner160 - 1512 kW | Natural Gas | ModulatingView specs
RS 150 TCGas Burner300 - 1860 kW | Natural Gas | Two-stage progressiveView specs
RS 150/M TCGas Burner300 - 1860 kW | Natural Gas | ModulatingView specs
RS 190 TCGas Burner470 - 2290 kW | Natural Gas | Two-stage progressiveView specs
RS 190/M TCGas Burner470 - 2290 kW | Natural Gas | ModulatingView specs
RS 250/M MZGas Burner600 - 2650 kW | Natural Gas | ModulatingView specs
RS34/M TCGas Burner45 - 390 kW | Natural Gas | ModulatingView specs
RS44/M TCGas Burner80 - 550 kW | Natural Gas | ModulatingView specs
RS50/M TCGas Burner80 - 580 kW | Natural Gas | ModulatingView specs
RS310/M MZGas Burner1300 - 3300 kW | Natural Gas | ModulatingView specs
RS410/M MZGas Burner1300 - 4300 kW | Natural Gas | ModulatingView specs
RS510/M MZGas Burner1300 - 5300 kW | Natural Gas | ModulatingView specs
RS610/M MZGas Burner1300 - 6300 kW | Natural Gas | ModulatingView specs

FAQ

What does the Riello RS Series collection cover?

Riello RS gas-burner families include staged and modulating versions. In the documented designation system, /M identifies mechanical-cam modulation, /E identifies electronic-cam control and TC identifies a standard-length combustion head. Selection requires the complete designation, firing diagram and gas-train requirements.

Does a shared series name establish replacement compatibility?

No. Compare the complete designation, supported controller or interfaces, operating limits and document revision. A family document is not a verified replacement cross-reference.