The Azbil AUD100C1000 is a highly sensitive industrial flame detector, explicitly developed to interface with Azbil burner control relays. Utilizing an advanced ultraviolet (UV) sensing tube, it reliably detects the UV radiation emitted by gas and oil flames while remaining immune to refractory glare and incandescent background heat. Coupled with Azbil's dynamic self-checking systems, it forms a definitive safety interlock for continuous-duty combustion applications.

Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.

Catalog Specifications

Sensor Type

Ultraviolet (UV) Flame Detector

Spectral Sensitivity

190 - 260 nm (Solar Blind)

Ambient Temperature

-20°C to +100°C (Standard)

Housing Material

Die-cast Aluminum (AUD series)

Protection Class

IP 65 (AUD series)

Selection Notes & Data Verification

The AUD100C1000 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Application Checks

Equipment and fuel compatibility
Control sequence and interfaces
Operating envelope
Installation documentation

Related Models

Related Knowledge

FAQ

What is Azbil AUD100C1000 used for?

Azbil AUD100C1000 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can AUD100C1000 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing AUD100C1000?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Plan Your Selection

Use the selection guide to organize model, operating condition, and documentation checks.