Azbil 129464NJ Flame Detector
Technical specifications and related model references.
Product Overview
The Azbil 129464NJ is a highly sensitive industrial flame detector, explicitly developed to interface with Azbil burner control relays. Utilizing an advanced ultraviolet (UV) sensing tube, it reliably detects the UV radiation emitted by gas and oil flames while remaining immune to refractory glare and incandescent background heat. Coupled with Azbil's dynamic self-checking systems, it forms a definitive safety interlock for continuous-duty combustion applications.
Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.
Catalog Specifications
Sensor Type
Ultraviolet (UV) Flame Detector
Spectral Sensitivity
190 - 260 nm (Solar Blind)
Ambient Temperature
-20°C to +100°C (Standard)
Housing Material
Die-cast Aluminum (AUD series)
Protection Class
IP 65 (AUD series)
Component Type
Replacement UV Tube / Accessory
Selection Notes & Data Verification
The 129464NJ page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Application Checks
Related Models
Related Knowledge
FAQ
What is Azbil 129464NJ used for?
Azbil 129464NJ is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can 129464NJ replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing 129464NJ?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Plan Your Selection
Use the selection guide to organize model, operating condition, and documentation checks.
Selection Guide