Skip to content
Burner.wikiKNOWLEDGE HUB
Riello

Riello GULLIVER RG3D Oil Burner

The Gulliver RG3D is a two-stage light oil burner in Riello’s RGD range. Riello lists product codes 3739450 and 3739454 under this model name.

Riello — Gulliver RGD model codes and manuals

Product Overview

Riello GULLIVER RG3D

The Gulliver RG3D is a two-stage light oil burner in Riello’s RGD range. Riello lists product codes 3739450 and 3739454 under this model name.

Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.

Catalog Specifications

Capacity (kW)

65/83 – 178 kW

Operation Mode

Two-stage

Fuel Type

Light Oil

Selection Notes & Data Verification

Manufacturer references

The capacity follows the two-stage notation in Riello’s technical data table. Use the product code on the nameplate to find the manual and firing diagram for the installed burner.

The GULLIVER RG3D page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Application Checks

Equipment and fuel compatibility
Control sequence and interfaces
Operating envelope
Installation documentation

Related Knowledge

FAQ

What is Riello GULLIVER RG3D used for?

Riello GULLIVER RG3D is referenced as a oil burner for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can GULLIVER RG3D replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing GULLIVER RG3D?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Plan Your Selection

Use the selection guide to organize model, operating condition, and documentation checks.