SiemensControllers

Siemens LAL1.25 110V Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Siemens LAL1.25 110V is an automatic burner control unit optimized for atomizing oil burners of medium to high capacity. It orchestrates the entire burner operating cycle, including oil preheating, pre-purging, ignition, and continuous flame supervision via specialized photoresistive detectors. Essential for industrial oil-fired boilers, thermal fluid heaters, and heavy-duty furnaces, the LAL1.25 110V provides fail-safe monitoring and rapid shutdown in the event of fuel atomization or ignition failure. The LAL series stands out for its rugged construction, precise timing mechanisms, and extensive integration capabilities within complex industrial combustion safety chains.

Key Features

  • Component Type: Controllers
  • Operating Voltage: AC 110V / 120V
  • Protection Class: IP40
  • Original Siemens quality and reliability
  • Compliant with relevant CE / DIN EN standards

Technical Specifications

Verification Required

Protection Class

IP40

Selection Notes & Data Verification

The LAL1.25 110V page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Siemens LAL1.25 110V used for?

Siemens LAL1.25 110V is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can LAL1.25 110V replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing LAL1.25 110V?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if LAL1.25 110V fits your combustion chamber and backpressure requirements.

Contact Engineering