Honeywell C7061A1079 Flame Detector
Technical specs, application notes, replacement checks, and related model references.
Product Overview
The Honeywell C7061A1079 is a heavy-duty, self-checking ultraviolet (UV) flame detector engineered for continuous-operation industrial burner systems. It features an internal electro-mechanical shutter that periodically blocks the UV radiation to test the sensor's functionality, ensuring absolute fail-safe operation during uninterrupted firing cycles. Vital for power generation boilers, large process heaters, and petrochemical furnaces, the C7061A1079 guarantees that any component failure results in an immediate safety shutdown. This dynamic self-checking capability makes it the premier choice for applications requiring 24/7 combustion safety compliance.
Technical Specifications
Verification RequiredVerification Status
Core model identity has been collected. Electrical parameters, terminal layout, replacement compatibility, and safety timing should be verified against official manufacturer documentation before field use.
Selection Notes & Data Verification
The C7061A1079 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Typical Applications
Related Models
Related Knowledge
FAQ
What is Honeywell C7061A1079 used for?
Honeywell C7061A1079 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can C7061A1079 replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing C7061A1079?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Need Engineering Help?
Our experts can help you verify if C7061A1079 fits your combustion chamber and backpressure requirements.
Contact Engineering