FiorentiniGas Pressure Regulators

Fiorentini 30161 Gas Valve

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Pietro Fiorentini 30161 is a precision gas pressure regulator (governor) designed for maximum accuracy and stability in industrial burner applications. Equipped with a highly sensitive compensating diaphragm, it effectively neutralizes inlet pressure variations to deliver a perfectly stable downstream pressure to the burner head. Its robust design includes an internal safety relief valve and exceptional shut-off characteristics (zero flow capability), making it an indispensable component for safe and efficient combustion.

Technical Specifications

Component Type

Gas Pressure Regulator / Governor

Regulator Class

Class A (EN 88-1 / EN 88-2)

Max Inlet Pressure

500 mbar (Standard)

Safety Features

Internal relief valve & compensation diaphragm

Connection Type

Threaded (ISO 7/1)

Approvals

CE, DVGW

Selection Notes & Data Verification

The 30161 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Fiorentini 30161 used for?

Fiorentini 30161 is referenced as a gas valve for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can 30161 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing 30161?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if 30161 fits your combustion chamber and backpressure requirements.

Contact Engineering