FiorentiniGas Filters

Fiorentini 10604 Gas Valve

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Pietro Fiorentini 10604 is a high-capacity industrial gas filter engineered to protect downstream combustion and regulation equipment from particulate contamination. Featuring a highly durable die-cast aluminum housing and an easily replaceable synthetic fiber filter cartridge, it efficiently traps dust, pipe scale, and rust with a minimal pressure drop. Manufactured in Italy to rigorous European standards, it ensures the safe and continuous operation of gas trains for natural gas, LPG, and non-corrosive biogases.

Technical Specifications

Component Type

Industrial Gas Filter

Filtration Grade

≤ 50 µm (Standard)

Filter Material

Washable Synthetic Fiber

Housing Material

Die-cast Aluminum alloy

Connection Type

Threaded (ISO 7/1)

Approvals

CE, UNI EN 126

Selection Notes & Data Verification

The 10604 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Fiorentini 10604 used for?

Fiorentini 10604 is referenced as a gas valve for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can 10604 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing 10604?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if 10604 fits your combustion chamber and backpressure requirements.

Contact Engineering