Fema DGM506 Burner Accessory
Technical specifications and related model references.
Product Overview
The FEMA (Honeywell) DGM506 is a highly reliable gas pressure switch designed specifically for monitoring and controlling the pressure of fuel gases and air in industrial burner systems. Certified by DVGW according to EN 1854, it provides critical safety interlock capabilities by triggering burner shutdown when pressure drops below or exceeds safe operational thresholds. Its robust die-cast aluminum housing and precision microswitch ensure exceptional durability and repeatability in demanding combustion environments.
Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.
Catalog Specifications
Application
Fuel Gases (DVGW approved) & Air
Switching Function
SPDT Microswitch
Housing Material
Die-cast Aluminum (GD Al Si 12)
Protection Class
IP 54 (IP 65 optional)
Approvals
DVGW (EN 1854), CE
Selection Notes & Data Verification
The DGM506 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Application Checks
Related Models
Related Knowledge
FAQ
What is Fema DGM506 used for?
Fema DGM506 is referenced as a burner accessory for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can DGM506 replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing DGM506?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Plan Your Selection
Use the selection guide to organize model, operating condition, and documentation checks.
Selection Guide