Skip to content
Burner.wikiKNOWLEDGE HUB
DungsSolenoid Valves

Dungs MVD2065/5 Gas Valve

Technical specifications and related model references.

Product Overview

The DUNGS MVD2065/5 is an authoritative Class A Single-stage Solenoid Valve designed for the safe shut-off and regulation of fuel gases in industrial burner applications. Manufactured to the highest German engineering standards, it provides rapid closing times (< 1s) and fail-safe operation to prevent unburned gas leakage. With its robust die-cast aluminum body and high flow capacity, the MVD2065/5 is a cornerstone of modern gas train architectures, ensuring strict compliance with EN 161 and international safety directives.

Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.

Catalog Specifications

Valve Class

Class A, Group 2 (EN 161)

Max Operating Pressure

500 mbar (Typical)

Closing Time

< 1 second

Housing Material

Die-cast Aluminum

Protection Class

IP 54 (Standard) / IP 65 (Optional)

Opening Profile

Fast opening (< 1s)

Selection Notes & Data Verification

The MVD2065/5 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Application Checks

Equipment and fuel compatibility
Control sequence and interfaces
Operating envelope
Installation documentation

Related Models

Related Knowledge

FAQ

What is Dungs MVD2065/5 used for?

Dungs MVD2065/5 is referenced as a gas valve for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can MVD2065/5 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing MVD2065/5?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Plan Your Selection

Use the selection guide to organize model, operating condition, and documentation checks.

Selection Guide