Dungs LGW500A2 Pressure Switch
The complete designation was not found in the consulted manufacturer documents. This is an evidence gap, not proof that the product does not exist.
DUNGS 214749 - LGW A2Product Overview
LGW500A2 is listed in the DUNGS GW and LGW catalog group. DUNGS GW and LGW pressure switches serve different monitoring applications. GW A5 and A6 cover gas and air pressure monitoring; LGW A2 covers air, flue-gas and exhaust-gas applications, including differential-pressure monitoring. Medium, range and switching behavior must match the specific variant.
Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.
Catalog Specifications
Application
Gas, Air, Flue gases
Switching Function
SPDT Microswitch
Max Operating Pressure
500 mbar (Typical)
Contact Material
Ag (Gold-plated optional)
Approvals
CE (EN 1854), FM, CSA
Selection Notes & Data Verification
Manufacturer references
The complete designation was not found in the consulted manufacturer documents. This is an evidence gap, not proof that the product does not exist.
The LGW500A2 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Application Checks
Related Models
View GW seriesRelated Knowledge
FAQ
What is Dungs LGW500A2 used for?
Dungs LGW500A2 is referenced as a pressure switch for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can LGW500A2 replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing LGW500A2?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Plan Your Selection
Use the selection guide to organize model, operating condition, and documentation checks.
Selection Guide