Bentone BG450

Bentone gas burner designed for high efficiency and reliability. The BG series is a robust mid-to-large range burner intended for industrial processes or heating medium-to-large commercial buildings.

Key Features

  • Energy saving and low fuel consumption
  • Single-stage operation
  • Approved according to EN 676 standard
  • Designed for easy maintenance

Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.

Catalog Specifications

Capacity (kW)

90 - 550 kW

Operation Mode

Single-stage

Fuel Type

Natural Gas / LPG / Biogas

Selection Notes & Data Verification

The BG450 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Application Checks

Equipment and fuel compatibility
Control sequence and interfaces
Operating envelope
Installation documentation

Related Knowledge

FAQ

What is Bentone BG450 used for?

Bentone BG450 is referenced as a gas burner for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can BG450 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing BG450?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Plan Your Selection

Use the selection guide to organize model, operating condition, and documentation checks.