Resideo WT8840A1500 Flame Detector
Technical specs, application notes, replacement checks, and related model references.
Product Overview
The Resideo WT8840A1500 is a high-performance commercial water heater control valve, integrating highly accurate temperature regulation, an advanced gas control mechanism, and an LED status indicator. Designed as a direct replacement for traditional mechanical gas valves, it utilizes a thermopile-powered microcomputer for tighter temperature differentials and enhanced safety. It is the authoritative choice for maintaining precise commercial hot water supply while ensuring rigorous safety compliance.
Technical Specifications
Gas Type
Natural Gas or LP (Configuration Dependent)
Capacity
Up to 100,000 BTU/hr (Typical)
Power Source
Thermopile (No external power required)
Temperature Range
Adjustable up to 160°F (71°C)
Connection Size
1/2 inch NPT
Selection Notes & Data Verification
The WT8840A1500 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Typical Applications
Related Models
Related Knowledge
FAQ
What is Resideo WT8840A1500 used for?
Resideo WT8840A1500 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can WT8840A1500 replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing WT8840A1500?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Need Engineering Help?
Our experts can help you verify if WT8840A1500 fits your combustion chamber and backpressure requirements.
Contact Engineering