Skip to content
ResideoIntermittent Pilot Commercial Solenoid Valves

Resideo VR8204M1091 Gas Valve

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Resideo VR8204M1091 is a premium Intermittent Pilot Combination Gas Control Valve. Serving as the critical gas flow regulation component in commercial heating applications, it integrates a manual valve, two automatic operators, and a pressure regulator into a single, compact body. This dual-valve architecture guarantees absolute shutoff upon flame failure. Widely deployed in commercial boilers, furnaces, and radiant heaters, the VR8204M1091 sets the standard for reliable gas train safety.

Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.

Catalog Specifications

Valve Type

Dual Automatic Valve (Intermittent Pilot)

Voltage

24 V AC (60 Hz)

Capacity

Up to 200,000 BTU/hr (1 in. pressure drop)

Pressure Regulator Setting

3.5 in. wc (Natural Gas) / 10.0 in. wc (LP)

Inlet/Outlet Connections

1/2 in. NPT

Selection Notes & Data Verification

The VR8204M1091 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Application Checks

Equipment and fuel compatibility
Control sequence and interfaces
Operating envelope
Installation documentation

Related Models

Related Knowledge

FAQ

What is Resideo VR8204M1091 used for?

Resideo VR8204M1091 is referenced as a gas valve for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can VR8204M1091 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing VR8204M1091?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Plan Your Selection

Use the selection guide to organize model, operating condition, and documentation checks.

Selection Guide