ResideoFlame Detectors

Resideo C554A1463 Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The Resideo C554A1463 is an industrial-grade flame detection sensor designed to interface seamlessly with primary burner control units. Utilizing advanced optical sensing technologies—such as cadmium sulfide (Cad Cell) for oil flames or infrared (IR) for gas/oil applications—it delivers instantaneous flame verification. Its authoritative sensitivity and robust housing prevent nuisance lockouts caused by refractory glare, ensuring optimal safety and efficiency in complex combustion systems.

Technical Specifications

Sensor Type

Cadmium Sulfide (Cad Cell) Flame Detector

Application

Oil Burner Flame Sensing

Mounting

Mounting Bracket Included

Lead Length

Varies by configuration

Approvals

UL Listed, CSA Certified

Selection Notes & Data Verification

The C554A1463 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Resideo C554A1463 used for?

Resideo C554A1463 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can C554A1463 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing C554A1463?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if C554A1463 fits your combustion chamber and backpressure requirements.

Contact Engineering