LamtecCables

Lamtec VSM100 667R0200-1 Flame Detector

Technical specs, application notes, replacement checks, and related model references.

Product Overview

The LAMTEC VSM100 667R0200-1 is a critical microprocessor-based component of the highly acclaimed LAMTEC burner management architecture (such as the BT300 series). Designed to handle complex combustion control tasks—ranging from electronic fuel/air ratio modulation to precise variable speed drive (VSD) control—it drastically improves burner efficiency and reduces emissions. Its modular design allows for flexible system expansion and easy configuration via intuitive digital interfaces.

Technical Specifications

Component Type

Variable Speed Module (VSD Control)

System Architecture

LAMTEC Modular Control Network

Communication

CAN-bus / Modbus / Profibus (Optional)

Safety Standard

EN 298 / SIL 3 compliant architecture

Application

Industrial & Commercial Burners

Selection Notes & Data Verification

The VSM100 667R0200-1 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.

Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.

Typical Applications

Industrial Boilers
Process Heating
Furnaces & Kilns
Thermal Oxidizers

Related Models

Related Knowledge

FAQ

What is Lamtec VSM100 667R0200-1 used for?

Lamtec VSM100 667R0200-1 is referenced as a flame detector for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.

Can VSM100 667R0200-1 replace another model?

Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.

What should be checked before installing VSM100 667R0200-1?

Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.

Documentation Note

Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.

Before replacement
  • Check supply voltage and frequency.
  • Confirm terminal layout and safety interlocks.
  • Verify flame detector or actuator compatibility.

Need Engineering Help?

Our experts can help you verify if VSM100 667R0200-1 fits your combustion chamber and backpressure requirements.

Contact Engineering