Lamtec BT335 667R1350-1 Burner Controller
Technical specs, application notes, replacement checks, and related model references.
Product Overview
BT335 667R1350-1 is listed in the LAMTEC BurnerTronic BT300 catalog group. LAMTEC BurnerTronic BT300 combines burner sequencing with electronic fuel-air ratio control. Features depend on the BT variant and installed modules. Check the full device designation, firmware, parameter set, actuators and flame monitoring arrangement.
Recorded catalog values are provided for comparison. Verify the complete model suffix and document revision before use.
Catalog Specifications
Verification RequiredVerification Status
Core model identity has been collected. Electrical parameters, terminal layout, replacement compatibility, and safety timing should be verified against official manufacturer documentation before field use.
Selection Notes & Data Verification
Manufacturer references
The LAMTEC order table (page 42) pairs BT335 with 667R1335-1 (230 VAC) or 667R1335-2 (120 VAC), not the recorded 667R1350-1. Verify the nameplate/order code; the catalog identifier is retained. SIL 3 claims are not transferred from BT331/BT341.
The BT335 667R1350-1 page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Application Checks
Related Models
View BT300 seriesRelated Knowledge
FAQ
What is Lamtec BT335 667R1350-1 used for?
Lamtec BT335 667R1350-1 is referenced as a burner controller for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can BT335 667R1350-1 replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing BT335 667R1350-1?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Plan Your Selection
Use the selection guide to organize model, operating condition, and documentation checks.
Selection Guide