The Pietro Fiorentini 31167/F is a highly versatile combination device that integrates a precision gas pressure regulator and a high-capacity gas filter into a single, compact unit. This space-saving design not only reduces installation time and gas train footprint but also ensures the regulator's internal mechanisms are permanently protected from particulate damage. It provides flawless downstream pressure control, compensating for upstream fluctuations, and is ideal for high-efficiency commercial and industrial burner systems.
Technical Specifications
Component Type
Filter-Regulator Combination Unit
Regulator Class
Class A (EN 88-1 / EN 88-2)
Filtration Grade
≤ 50 µm (Replaceable cartridge)
Safety Features
Integrated compensation diaphragm
Connection Type
Flanged (EN 1092)
Approvals
CE, UNI EN 126 & EN 88
Selection Notes & Data Verification
The 31167/F page is structured for engineering comparison: confirm the product type, firing range, fuel type, operating mode, electrical supply, and safety approvals against the manufacturer datasheet before specifying the burner or component.
Burner.wiki normalizes product data for discovery and comparison, but final selection should account for combustion chamber backpressure, local emission limits, control sequence requirements, and site commissioning conditions.
Typical Applications
Related Models
Related Knowledge
FAQ
What is Fiorentini 31167/F used for?
Fiorentini 31167/F is referenced as a gas valve for industrial combustion systems. Verify the exact application against the burner documentation, control cabinet wiring, and manufacturer datasheet.
Can 31167/F replace another model?
Replacement depends on voltage, safety timing, wiring terminals, flame supervision method, mechanical fit, and local combustion safety requirements.
What should be checked before installing 31167/F?
Check supply voltage, burner sequence, fuel type, pressure or capacity range, detector compatibility, safety loop configuration, and the equipment nameplate before commissioning.
Documentation Note
Technical documentation should be verified against the manufacturer datasheet, burner cabinet wiring diagram, and equipment nameplate before installation or replacement.
- Check supply voltage and frequency.
- Confirm terminal layout and safety interlocks.
- Verify flame detector or actuator compatibility.
Need Engineering Help?
Our experts can help you verify if 31167/F fits your combustion chamber and backpressure requirements.
Contact Engineering